G8MNY > TECH 07.08.04 01:10l 43 Lines 1815 Bytes #999 (0) @ WW
BID : 4500_GB7CIP
Read: GUEST
Subj: Alinco Rotator info
Path: DB0FHN<DB0RGB<OK0PPL<DB0RES<ON0AR<EB2BJX<GB7YKS<GB7SYP<GB7COV<GB7YFS<
GB7CIP
Sent: 040806/1204Z @:GB7CIP.#32.GBR.EU #:4500 [Caterham] $:4500_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To : TECH@WW
This is basic & reliable rotator with manual swicth contols & regulated meter
heading readout.
DIAGRAM
LÄoÄÄoÄ¿ ÚÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 6 *ÄÄÄÄÄÄÄ¿
Fuse )||( ³ ³ ³
)||( ³ 33R left 2x 8ê ³
)||( 24v ³ ³ ÚÄo\ oÄÄÄÂÄÄÄÄÄÄÄÄÄÄ* 5 *Ä())))Ä´
NÄo/'oÄÙ ||( ³ ³ ³ ===130u~ ===== ³
ON ÃÄÄÄÄ)ÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄÄÁÄo/ oÄÄÄÁÄÄÄÄÄÄÄÄÄÄ* 4 *Ä())))ÄÙ
³ ³ _³_ Right MOTOR
³ 120R \_/
³ ³ ÃÄÄÄÂÄÄÄÄÄ¿
³ ³ ³ 470R ³/
³ ³ ³ ÃÄÄÄ´ REGULATOR
³ ³ ³ ³ ³\e
³ ³ ³ ³ ÀÄ100RÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄ* 2 *ÄÄÄÄ¿
³ LAMP +³ ³ ³ ³
³ ³ === ÃÄÄÄ¿ 10n=== CAL ROTOR
³ ³ 470u³ _³_, \³,, ÃÄÄMeterÄ8KÄÄÄ* 3 *ÄÄÄ>POT
³ ³ ³ '/_\ ÃÄÄÄÄÄÄ´ PRESET 500R
³ ³ ³ 9v³ e/³''FB ³ ³
³ ³ ³ ³ ³ 27R ³
ÀÄÄÄÄÁÄÄÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄ* 4 *ÄÄÄÄÙ
CURRENT LIMITER
* = External Connection
MODS
As with othwr rotators the motor is well over run & a high wattage low value
R (eg 4ê 10W) in series with the motor common (*5*) will increase motor run
time before it overheats if high use is needed.
Also a 0u5 Cap across the mains corrects the transformer power factor for /P
operation.
Why Don't U send an interesting Bul?
73 de John G8MNY @ GB7CIP
Read previous mail | Read next mail
| |