G8MNY  > TECH     07.08.04 01:10l 43 Lines 1815 Bytes #999 (0) @ WW
BID : 4500_GB7CIP
Read: GUEST
Subj: Alinco Rotator info
Path: DB0FHN<DB0RGB<OK0PPL<DB0RES<ON0AR<EB2BJX<GB7YKS<GB7SYP<GB7COV<GB7YFS<
      GB7CIP
Sent: 040806/1204Z @:GB7CIP.#32.GBR.EU #:4500 [Caterham] $:4500_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To  : TECH@WW

This is basic & reliable rotator with manual swicth contols & regulated meter
heading readout. 

DIAGRAM
LÄoÄÄoÄ¿    ÚÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ* 6 *ÄÄÄÄÄÄÄ¿
  Fuse  )||(     ³     ³                                          ³
        )||(     ³    33R          left                   2x 8ê   ³
        )||( 24v ³     ³          ÚÄo\ oÄÄÄÂÄÄÄÄÄÄÄÄÄÄ* 5 *Ä())))Ä´
NÄo/'oÄÙ ||(     ³     ³          ³       ===130u~          ===== ³
  ON        ÃÄÄÄÄ)ÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄÄÁÄo/ oÄÄÄÁÄÄÄÄÄÄÄÄÄÄ* 4 *Ä())))ÄÙ
            ³    ³    _³_          Right                    MOTOR
            ³   120R  \_/
            ³    ³     ÃÄÄÄÂÄÄÄÄÄ¿
            ³    ³     ³ 470R  ³/ 
            ³    ³     ³   ÃÄÄÄ´ REGULATOR
            ³    ³     ³   ³   ³\e  
            ³    ³     ³   ³     ÀÄ100RÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄ* 2 *ÄÄÄÄ¿
            ³  LAMP   +³   ³            ³                      ³ 
            ³    ³    ===  ÃÄÄÄ¿    10n===       CAL         ROTOR
            ³    ³ 470u³  _³_,  \³,,    ÃÄÄMeterÄ8KÄÄÄ* 3 *ÄÄÄ>POT
            ³    ³     ³ '/_\    ÃÄÄÄÄÄÄ´       PRESET        500R
            ³    ³     ³ 9v³   e/³''FB  ³                      ³
            ³    ³     ³   ³   ³       27R                     ³
            ÀÄÄÄÄÁÄÄÄÄÄÁÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄ* 4 *ÄÄÄÄÙ
                            CURRENT LIMITER 
                                                       * = External Connection

MODS
As with othwr rotators the motor is well over run & a high wattage low value
R (eg 4ê 10W) in series with the motor common (*5*) will increase motor run
time before it overheats if high use is needed.

Also a 0u5 Cap across the mains corrects the transformer power factor for /P
operation.
 


Why Don't U send an interesting Bul?
73 de John G8MNY @ GB7CIP