OpenBCM V1.13 (Linux)

Packet Radio Mailbox

DB0FHN

[JN59NK Nuernberg]

 Login: GUEST





  
MM0BQM > AMTOR    12.09.98 12:14l 59 Lines 2570 Bytes #-10297 (0) @ WW
BID : 2D0113MM0BQM
Read: DB9WK UA6HJQ DL1LAE GUEST
Subj: Re: Advice-HAMCOM
Path: DB0ZDF<DB0SRS<DB0MW<DB0ERF<DB0SHG<DB0HSK<PI8DRS<PI8DAZ<PI8APD<PI8WNO<
      PI8UTR<PI8GCB<PI8WFL<PI8VNW<GB7PMB<GB7WXM<GB7DEE<GB7OAR<GB7BOB<GB7FYL<
      GB7FUR<GB7IOM<GB7BMR<GB7SAN<GB7AYR
Sent: 980910/1617Z @:GB7AYR.#78.GBR.EU #:16221 [Irvine] Z:KA11 N:GM0JQE FBB7.00
From: MM0BQM@GB7AYR.#78.GBR.EU
To  : AMTOR@WWW


M1AHG wrote:-
> I seem to be getting numbers and letters with lots of boxes. Plus red 
> letters and numbers. I seem to get a lock and the correction counter 
> goes passed -10, about -40!! :-()
> 
> What is going on?? :-( I have read and re-read them manual but it does 
> not help at all. What am I doing wrong? Could someone plus give me step 
> by step instuction on tuning into AMTOR and using it?

Does this help : -

                                    - 19 -

         HamComm 3.0                Manual              June 15th 1994
 
 
         So  the  clock  has to be corrected.  To find the 'clockcorr'
         value  for  a specific PC, an ARQ reference signal is needed.
         This  could be an AMTOR station but it is usually easier with
         a SITOR signal.  If you have a receiver that can tune outside
         the  amateur  bands,  try  to  find  a  SITOR  station around
         2020kHz,  4200kHz,  6320kHz  or  8400kHz.   We  need a strong
         signal with information blocks.  Select AMTOR ARQ LISTEN mode
         (F4) and tune to the signal.

         A correction counter is shown in the lower left corner of the
         RX  window,  to  the  right  of  link  status  display.   The
         correction  counter  will change as soon as HamComm is locked
         on  the  signal  and  starts  to decode.  The link status now
         displays  TRFC, REPT, REQU or IDLE.  Hit the ESC key to reset
         the  counter and watch the counter.  We need to know how many
         seconds  it  takes until the counter has reached the value 10
         or  -10.   If there are interruptions in the transmission you
         will  have  to  start over again.  Repeat the procedure a few
         times to make sure you got the right value.  If it takes more
         than  two minutes to reach the final count your PC happens to
         be accurate enough.

         The  clockcorr  value is the number of seconds times 100.  If
         the  count  is  negative  then  the  clockcorr  value is also
         negative.   Example:  The  counter reached -10 in 43 seconds.
         The clockcorr value is therefore -4300

         The  clockcorr  setting  has to be changed in HC.CFG .  Using
         your  favourite  editor  find  the line "set clockcorr 0" and
         change  it  to  the  value calculated before.  With the right
         value   the  correction  count  will  be  stable  during  ARQ
         reception.


73 - Bob, MM0BQM @ GB7AYR

Message timed: 17:16 on 10 Sep 98


Read previous mail | Read next mail


 21.11.2026 17:24:37lGo back Go up