G8MNY > TECH 07.07.26 08:52l 56 Lines 2448 Bytes #999 (0) @ WW
BID : 64331_GB7CIP
Read: OE5RCO DJ6UX GUEST
Subj: Thermostatic Iron Repair
Path: DB0FHN<DB0RKB<DK0WUE<HB9ON<HB9ON<PI8ZTM<VE3CGR<GB7OSW<GB7BED<EI2GYB<
GB7CIP
Sent: 260707/0630Z @:GB7CIP.#32.GBR.EURO #:64331 [Caterham Surrey GBR]
From: G8MNY@GB7CIP.#32.GBR.EURO
To : TECH@WW
By G8MNY (Corrected Jul 22)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
I pickup a "Weller" type iron by "AdcolA" that has electronic temperature
control, using a negative temperature thermistor with the element. This is
rather than "Magnetic Curie Point" temperature switch of Weller system, or a
thermocouple & sensitive op amp system!
In the handle was a 14 pin control chip which was dud & did not trigger the
triac. So I developed this much simpler 1 transistor circuit as a replacement.
24V o컫컴컴컴컴컴컴컴컴컴컴컴컴컴컴컴컴커
AC 1K �
2A _�_ �
\_/ 12R The thermistor is about 50K cold
쳐컫컴컴컴컫컴컴컴컴컴컴컴커 48W and less than 1K hot. The 3K9 &
� � � + 2K Element 150R set lowest & highest temp
� +� NTC 旼늘컴컫컴� � with my thermistor.
10V_�_=== Therm �47u �/ _�_ �
'/_\ �100u 쳐컴쩡좔컴캑 \_/=LED �
� � Temp � BC337�\e � ___�___
� � 旼>pot � � � _\/_/\_
� � � 2K � � �____/ �3A
� � 읕컴� 3K9 � 쿟riac
� � 150 � � �
0V o컴좔컨컴컴컴컨컴컨컴컴컴컴좔컴컴컴컴�
iron earth
E컴컴컴컴컴컴컴컴컴컴컴컴컴컴컴컴컴컴컴컴�
///
The traic is no longer phase fired, as I assume the original IC could do, but a
simple on off including an added status LED (used on some of their irons).
HOW IT WORKS
The 100uF is charged up via 1K & diode to 10V when the zener conducts. The
triac is turned on via the LED & 2K, giving full power to the heater element.
When the thermistor is hot enough (lower resistance) to put 0.6V on the NPN
base with the preset pot load, the NPN conducts, & bypasses the current going
through the LED and gate, keeping the triac off. The 47uF slows the action, so
the triac gets a chance to conduct on both half cycles & even a few on & off,
as shown on the flashing LED.
The circuit needs scoping to check the triac is firing OK on both + & - half
cycles, if not, damage can be done to very small 24V AC transformers!
Also see my Tech Bul on "Soldering Iron Economiser/Boost"
Why Don't U send an interesting bul?
73 De John, G8MNY @ GB7CIP