For PA with RF/DC sense switching (as some rigs put out DC on Tx), that used a
diode to detect any +ve signals (RF/DC) from the transceiver to operate the PA
PTT system....
The time constants are OK for SSB & FM. The 22uF can be omitted for FM only.
TR1 & 2 BC107 etc, TR3 a TIP type PNP, D1 RF diode 1N4148 etc. D2 1N4001.
Rig o)ÄÄÂÄÄÄÄÂÄÄ´ÃÄÄÄÄ> RF to Drive Relay
³ 100k _³_ 1n
³ ³ \_/ ______+12-24V
³ ³ ³D1 ³/e
³ ³ ³ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄ´ TR3
³ ³ 22k ³ ³ ³\ PNP
³ ³ ³ ³ Ext oÄÄ¿ 470 ³ +Tx
³ ³ ³ ³/ PTT ³ LED ³ ÃÄÄÄÄ> Drive, O/P,
³ ³ ÃÄÄÄÄ´ TR1 ÃÄÄÄÄ´<ÃÄÄÙ ³ Bias, &
³ ³ ³ ³\e ³/ ³ Fan Relays
³ ³ === ÃÄÄ47kÄÂÄÄÄÄ´ TR2 ³
³ ³ ³10n ³+ ³ ³\e ³
³ ³ ³ === ÃÄÄÄÄÄÄ)ÄÄÄÄ150kÄÄÄÄÄÄÄÄ´
³ ³ ³ ³22u ³ ³ +ve _³_
³ ³ ³ ³ 10k ³ feedback /_\
³ ³ ³ ³ ³ ³ D2 ³
ÄÁÄÄÁÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄ
HOW IT WORKS
D1 detects RF & passes any rig DC to turn on TR1. TR1 turning on charges up the
22uF & makes TR3 initially conduct to give fast Tx attack. When 22uF is over
2V TR2 is turned on & passes higher base current into TR3 via a Tx LED ensuring
it is well turned on. The 150k +ve feedback ensure snap action (too low & it
may not switch off!)
External PTT earth can be put in/out on TR2 collector.
I have found it was heat sensitive, due to the sensitivity of the 1st NPN.
Why Don't U send an interesting bul?
73 De John, G8MNY @ GB7CIP