G8MNY > TECH 08.04.17 11:36l 95 Lines 4664 Bytes #-3455 (0) @ WW
BID : 40022_GB7CIP
Read: GUEST DK3UZ DF7EAV
Subj: Eagle DB120 Sound Meter
Path: DB0FHN<OE2XZR<OE5XBL<F1OYP<IZ3LSV<I0OJJ<I0OJJ<VE3UIL<GB7YEW<GB7CIP
Sent: 170408/0845Z @:GB7CIP.#32.GBR.EURO #:40022 [Caterham Surrey GBR]
>From g8mny%gb7cip.#32.gbr.euro@i0ojj.ampr.org Sat Apr 8 11:31:54 2017
Received: from i0ojj.ampr.org by i0ojj.ampr.org (JNOS2.0k.1) with SMTP
id AA2337 ; Sat, 08 Apr 2017 11:31:54 +0200
Message-Id: <40022_gb7cip@ve3uil.bbs>
>From: g8mny@gb7cip.#32.gbr.euro
X-JNOS-User-Port: Telnet (ve3uil @ 206.47.13.106) -> Sending message
From: G8MNY@GB7CIP.#32.GBR.EURO
To : TECH@WW
By G8MNY (Correction Feb 16)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
The is a simple cheap sound meter.
____ PCB LAYOUT
旼컴좔컴컨컴커 旼컴컴컴컴컴컴�
납~~~~~~~~~~납 � /~~~\ �
납 \ 납 쿜12쿘ETER쿣R2�
납 \ 납 � \___/ �
납__________납 40dBA-120dBA in 2 ranges � �
� ____� In built calibrator 쿣R1 __ �
� /~~\ � 넬� Q5 /~ ~\�
� � 납 납� 쿞WITCH�
� \__/ � 납쿔C \_ _/�
� ~~~~� 냅� VR3 ~~ �
� � � �
� EAGLE � 읏 旼컴� 粕
� � 쿣R5� 쿣R4�
� � 읕컴� 읕컴�
읕컴컴컴컴컴켸
CIRCUIT
旼컴컴쩡컴쩡컴쩡컴�2k2컴컴컴컴컴컴컴컫컴컴컴컴컴쩡<+ve
� 56k � � � � OPAMP
� + � �/ �+ � � The TD7120 provides
Mic캑쳐탠큂3 === � 56k fixed stable gain
� 4u7 � �\e �33u 7� 旼컴� � to drive the non the
� 56k � � Low 2�~\�3 56k � linear metering stage.
� � VR2쳐)컫컴컴컴훟<�2k2컴쩡컴큈A\ 6� � +
� � Mic �14k4 150k �7120>컨컴컴)컴늘컴3k3�>
� � cal � 쳐컴컴컴o 쳐컴� /읕쩡19k캑+ 10u
� � � �220 High +� 5�_/ 1 � ===
� � � � � 10u=== �4 ===3n3 �10u
읕컴컴좔컴좔컴좌좔컴컴컴컴컴컴컴좔컴컨컴컴좔컴컴좔<
읕훆R1컴혃 Cal
200 � 旼컴컫컴컫컴컴쩡�5k1컴<+ve
220k � 33k 33k �
PREAMPS � 3k9 � � 3k9
The 3 wire electret mic 읕컴컵컴늘�\ /졍쳐캑
& preamp Q3 is powered \� X �/
from a decoupled rail. Q2쳐컴� 읕컴큂1
e/� ASTABLE �\e
VR2 calibrates the mic 읕컴컴컫컴컴컴�
capsule & VR1 calibrates 100
the astable calibrate 컴좔컴<
oscillator Q1&2.
METER DRIVER oOff
+ve<컴컴컴컴컴컴컫컴컴쩡컴컴컴컴컴컴컴컴컴컴컫컴풽 旼컫컴쩡o<컴컫컴�
10k �/ 47u�+ \ / 2k2 쳐oHigh� �
쳐캑Q5 === 컴쩡� � 읕oCal � �
_�_ �\e +10u � Q7쳐컴켸 旼oBat � �
\_/ 쳐컴�560컴쩡늘컴쩡컴� � � � oOff� �
_�_ 쳐커 +� � � � � � � �
D1 \_/ �/e � ===10u � � � _�_ � � �
旼�>쳐� 쳐캑Q6 100k � � � � /_\' � === �+
� � �/ �\ � 旼좔� � � � � � � BATT
>컵�2k2컵컴쩡컴큂4 � � _�_ _�_ _�_ _�_ � � � � PP3
� � 100k �\e � � \_/ /_\ \_/ /_\ � � 쳐컴� � �
읕�<쳐� 읕컴컴)컴컴)컴�+ 쿏9 쿏8 쿏7 쿏6� � VR3 680 � �
D2 � 220 � === � � � � � � 50k � � �
� � � �10u � � � � � � � � � �
<컴컴컴�)컴컴컴쩡좔컴컨쩡좔컴�)컴컨컴컨컴�)컴좔컴컨컴컴컴�)컴컨컴좔켸
� 10u=== ===10u � � �
D3쳐�<쳐컨컴VR5컴좔컴컴컨컴캑>쳐컴컴)컴컴컴컴컫컴컴캑
� 5k D10 � VR4 33u=== Meter
D4읕�>쳐컴컴컴컴컴컴컴컴컴컴컴컴컴컴좔�2k컴컴컨컴컴켸
To get a usable 40dB scale on a meter quite a lot of compression is needed.
This circuit uses an AGC approach. Transistors Q4, 5 & 6 from a power amp to
drive the double voltage doubler bridge D6-10 rectified load of the meter &
also provide AGC with D3 & D4 making an variable input attenuator.
VR5 set the AGC log action & diodes D1 & D2 correct for over compression to get
the very linear 40dB scale. VR4 is the main calibrate & VR3 is the battery cal.
See my bul on "Sound Levels dBA dBB dBC".
Why don't U send an interesting bul?
73 de John G8MNY @ GB7CIP
Read previous mail | Read next mail
| |