I recently looked at a Freeview STB that had blown up (a Digilogic DSTB1000
which is the same as Goodmans GDB6). On first sight the SMPU design looks fine
like any other, with the normal safety features etc..

               ÚÄÄÄÂÄÄÂÄÄÄÄÄÂÄÄÄÄÂÄÄÄÂÄÄÄÄÄÄÄÄÂÄÄ¿    ÚÄ´>ÃÄÂÄ +30V
              _³_ _³_ ³     ³  200k ===10n    ³  ³ ||(
  F           /_\ /_\ ³     ³    ÀÄÄÄ´ Spike  ³   )|| ÃÄ´>ÃÄÂÄ
Äo-oÂÄÄ¿ ÚÄÄÂÄÄ´   ³  ³     ³       100 Damper³   )||(
L   ³  ³ ³  ³  ³   ³  ³+    ³+       ³   ÚÄÄÄÄ)ÄÄÙ || ÃÄ´>ÃÄÂÄ +12V
    ³  ()) === ³   ³ ===   ===       À´<ô    ³    ||(
   VDR ===  ³  ³   ³  ³4u7  ³C  _____    ³   2M    || ÃÄ´>ÃÄÂÄÄÄÄÂÄÄÂ+5V
    ³  ())  ³  ³   ³  ³     ³  ³  ÚÁÄÁÄÄÄÁ¿   R    ||(     1k    ³  ³
ÄÄÄÄÁÄÄÙ ÀÄÄÁÄÄ)ÄÄÄ´  ³     ³  ³  ) TNY265³   ³    TR ³    _³_   ³ ===
N             _³_ _³_ ³     ³  ³  ÀÂÄÂÄÂÄÂÙ   ³       ³opto\_/   ³  ³
              /_\ /_\ ³     ³  ³ n1³ ÀÂÙ ÃÄÄÄÄ´       ³     ³   10k ³
               ³D  ³  ³     ³  ³  === ³ _³_Z   \³<    ³      \³  ³  ³
               ³   ³  ³  L  ³  ³   ³  ³ /_\' e /³<    ³       ÃÄÄ´  ³
               ÀÄÄÄÁÄÄÁÄcccÄÁÄÄÁÄÄÄÁÄÄÁÄÄÁÄÄÄÄÙ       ³     e/³ 1k  ³
                        ===                           ÀÄÄÄÄÄÁÄÄÄÄÁÄÄÁÄ0V

WHAT WENT WRONG
The original fault was just an electrolytic "C" going open circuit (very
common & the cause of a lot of mains born RFI!). But the resultant failed
component count was so high much more than the STB was worth new!!

With the SMPSU IC now having no low Z Cap C to push the current through the
transformer, all the pulse current appear as high voltage across the small
decoupling choke L (1.5mH). This bypasses the spike damper that the protects
the IC from over voltage & the IC blows up. In doing so it took out the PCB
track near the 2M R (4x 500k surface mounts) to a spare transformer primary
winding TR, the control loop protection zener Z, the L itself, 2 of the surface
mount bridge diodes D, & of course the fuses both the PCB 3A fuse & plug 5A
one!

This is relatively modern kit that has had a very short lifetime. Why do makers
make it so unreliable! The circuit component count is quite high, I can't
really see why a simple conventional mains transformer would not have been a
much better design & far more reliable!

As far as this kit goes, powering it off rather than standy will extend the
life of the caps, but repeated power on surges will stress the other
components!


See my bul on "Faulting Tips".

Why Don't U send an interesting bul?

73 De John, G8MNY @ GB7CIP