OpenBCM V1.07b12 (Linux)

Packet Radio Mailbox

DB0FHN

[JN59NK Nuernberg]

 Login: GUEST





  
G8MNY  > TECH     03.07.05 10:27l 50 Lines 2290 Bytes #999 (0) @ WW
BID : 52725_GB7CIP
Read: GUEST OE7FMI
Subj: Soldering Iron Economiser/Boost
Path: DB0FHN<DB0FOR<DB0SIF<DB0FHK<DB0LJ<DB0RES<DK0WUE<SP7MGD<IK6PYS<W4JAX<
      CX2SA<GB7YFS<GB7CIP
Sent: 050703/0814Z @:GB7CIP.#32.GBR.EU #:52725 [Caterham] $:52725_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To  : TECH@WW

By G8MNY                                           (Updated Dec 04)
Suitable for 15-60W mains irons only!

  ............S T A N D....................           ....I R O N.........

   Fuse ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
 L o-oÄÄ(ÄÄÄÄÂÄÄÄÄÄÄ¿           +³  10uF       3 core    Boost     ³
   1A   ³   _³_    _³_          === 350v       cable     Press  SOLDERING
        ³   \_/    /_\           ÀÄÄÄÄÄÄÄ22RÄÄÄÄÄÄÄÄÄÄÄÄ> \       IRON
        ³    ³      ³                    1W                ³     ELEMENT
        ÀÄÄÄÄ´      ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÙ
             ³          Economize o    ³       or 4 core
       4x    ³      ÚÄÄÄÄÄÄÄÄÄÄÄÄÄo <ÄÄÙ       with earth
      1N4006_³_    _³_     Normal  Gravity
            /_\    \_/             Switch
 N ÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÙ
 E -------------------------------------------------------------------

When on the stand the mains fed to the iron is half wave only for economiser
mode (1/2 power), the iron rest on a suitably mounted stand micro switch that
is connected to one of the bridge diodes. When the iron is picked up, full wave
is restored for (normal power).

An added non locking press button switch mounted in the iron handle, this
boosts the power by connecting a 350V 10uF with a 22R in series (47uF/10R for
60W) housed in the stand (iron not earthed 3 core cable! Or use 4 core rubber
flex with an earth) resulting in approx 300V peak DC from the mains being used
for high power. This is approx 2x the normal power, hence the non locking press
switch!

Make sure all mains connections & switches are safe (properly shrouded heat-
shrink) to avoid shocks etc.

A neon (with series 220K) across iron can be used to indicate the power status.

     _._+340              _._                 _._    _._         _..__  _..__
    /   \                /   \               /   \  /   \       /     ''     ' 
0v.³.....³.......³   0v.³.....³______³   0v.³.....³³.....³  0v.³.............. 
  ³       ³     ³         
    NORMAL \_ _/          ECONOMY            FULL POWER          BOOST POWER
    MAINS    ' -340       « POWER             RAW  DC            SMOOTHED DC 


Why Don't U send an interesting bul?
 
73 De John, G8MNY @ GB7CIP


Read previous mail | Read next mail


 29.04.2025 21:22:16lGo back Go up