G8MNY  > TECH     22.03.04 09:24l 46 Lines 2178 Bytes #999 (0) @ WW
BID : 49310_GB7CIP
Read: DB0FHN GUEST OE7FMI
Subj: Soldering Iron Economiser/Boost
Path: DB0FHN<DB0THA<DB0ERF<DB0MRW<OK0PKL<OK0PPL<DB0RES<ON0AR<GB7CIP
Sent: 040322/0004Z @:GB7CIP.#32.GBR.EU #:49310 [Caterham] $:49310_GB7CIP
From: G8MNY@GB7CIP.#32.GBR.EU
To  : TECH@WW

By G8MNY                                           (new Graphics 12/03)
Suitable for 15-60W mains irons only!

  ............S T A N D....................           ....I R O N.........
        ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
 L ÄÄÄÄÄ(ÄÄÄÄÂÄÄÄÄÄÄ¿           +³  10uF       3 core    Boost     ³
        ³   _³_    _³_          === 350v       cable     Press  SOLDERING
        ³   \ /    / \           ÀÄÄÄÄÄÄÄ22RÄÄÄÄÄÄÄÄÄÄÄÄ> \       IRON
        ³   ÄÂÄ    ÄÂÄ                                     ³     ELEMENT
        ÀÄÄÄÄ´      ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÙ
             ³          Economize o    ³       or 4 core
       4x    ³      ÚÄÄÄÄÄÄÄÄÄÄÄÄÄo <ÄÄÙ       with earth
      1N4006_³_    _³_     Normal  Gravity
            / \    \ /             Switch
            ÄÂÄ    ÄÂÄ
 N ÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÙ

When on the stand the mains fed to the iron is half wave only for economiser
mode (1/2 power), the iron rest on a suitably mounted stand micro switch that
is connected to one of the bridge diodes. When the iron is picked up, full wave
is restored for (normal power).

An added non locking press button switch mounted on the iron, this boosts the
power by connecting a 350V 10uF with a 22R in series (47uF/10R for 60W) housed
in the stand (iron not earthed 3 core cable! Or use 4 core with earth)
resulting in approx 300V peak DC from the mains being used for high power. This
is approx 2x the normal power, hence the non locking press switch!

Make sure all mains connections & switches are safe (properly shrouded eg
heatshrink) to avoid shocks etc.

A neon (with series 220K) across iron can be used to indicate the power status.

     _._+340              _._                 _._    _._         _.__   _.__
    /   \                /   \               /   \  /   \       /    '-/    '- 
0v.³.....³.......³   0v.³.....³______³   0v.³.....³³.....³  0v.³.............. 
  ³       ³     ³         
    NORMAL \_ _/          ECONOMY            FULL POWER          BOOST POWER
    MAINS    ' -340       « POWER             RAW  DC              

/QSL
73 De John, G8MNY @ GB7CIP