DK8KV > QRP 13.08.98 11:34l 31 Lines 1168 Bytes #-10323 (0) @ EU
BID : 138802DB0MKA
Read: DG6MS DL2MHG GUEST
Subj: SG2020 add. Info
Path: DB0ZKA<DB0GPP<DB0LX<DB0CZ<F6KFG<DB0GE<DB0IZ<DB0MKA
Sent: 980813/1002z @:DB0MKA.#NRW.DEU.EU [HennefJO30PR DL3OE] $:138802DB0MKA
de DK8KV @ DB0MKA.#NRW.DEU.EU (Walter)
to QRP @ EU
SG-2020 Tech UPDATE
Updated: August 10, 1998
IMPORTANT INFORMATION UPDATE FOR OPERATORS OF THE SG-2020
HF SSB TRANSCEIVER AUGUST 1998
1-A. SG-2020 Procedure for power on or intermittent
power supply 'glitch display' @ 66 MHz.
The following procedure will cure the intermittent problem of the
SG-2020 "power on glitch" when the display reads 66 MHz.
(a) Power on radio
(b) Engage "channel scan" mode, by doing the following:
(a) depress and hold "CMD" button
(b) depress "MEM" button
(c) release "MEM" button
(d) release "CMD" button
NOTE: It may take up to 2 minutes to re-establish the memories, although it is
usually accomplished in just a few seconds.
(c) Exit "channel scan" by depressig any key.
2-A. SG-2020 Fuse
The SG-2020 has an internal, self-recovering, 5 amp fuse.
This fuse is not visible and it is mounted under the LPA PCB. The
fuse will recover within a few seconds after the short in the radio
has been removed.
Read previous mail | Read next mail
| |