LA2VY > MFJ 10.05.96 00:38l 28 Lines 1096 Bytes #999 (0) @ WW
BID : 35458_LA5A
Read: GUEST DF6VB
Subj: MFJ1278B KISS resets SOLVED!
Path: DB0KCP<HB9OS<HB9H<HB9OK<IW2FPO<IK2UUB<I2REO<IW2KTL<IK2FMJ<IW4CNQ<
I0XNH<I0LCJ<IW0FEF<IK8URC<IW8XGB<IK6EVF<IW7BLI<IW7BNO<IK7MXD<I7NRG<
I8WYA<I8CWM<IW8PHV<IW9CNZ<IT9ICS<IT9UBA<IT9PKB<IT9CGH<SV1BKN<LA5A
Sent: 960504/2006Z @:LA5A.ATA.Y.NOR.EU #:35458 [Alta] FBB5.15c $:35458_LA5A
From: LA2VY@LA5A.ATA.Y.NOR.EU
To : MFJ@WW
Hello!
3 weeks ago I sent out a message asking for help with my MFJ-1278B TNC which
resets it self to factory default parameters in KISS-mode after some time
without activity on the channel.
I got an answer from VK3BLW which solved the problem!
I understand that others are having the same problems, so I send this
bulletin @WW.
There is a secret KISS command 0xFD which turns off the "reset-to-default
-parameters-when-nothing-heard-for-a-while"-function !!
If you send the ASCII-characters C0 FD C0 (192 253 192) to the TNC
in KISSmode, it will not reset itself again!
You will have to resend the characters after a power failure, because the
TNC will then be reset.
I have made a small program that sends the magic characters to the TNC
(and also my favorite parameter settings) before I load BPQ. This works
excellent !
Hope that you find this information useful - it is not mentioned in the
manual.
73 de Kjell-Viggo, LA2VY@LA5A.ATA.Y.NOR.EU Date 960504 22:03
Internet E-mail: kjellvl@ksnet.ksedb.no
Modem: +47 78 44 29 10
Read previous mail | Read next mail
| |