OpenBCM V1.07b12 (Linux)

Packet Radio Mailbox

DB0FHN

[JN59NK Nuernberg]

 Login: GUEST





  
HB9ABX > ANT      14.07.06 11:54l 87 Lines 1930 Bytes #999 (90) @ WW
BID : J2E07VHB9EAS
Read: GUEST DK2ZA DL1SJN
Subj: RoomCap field strength data
Path: DB0FHN<DB0MRW<DB0FSG<DB0PV<DB0ZKA<DB0SIP<OE9XPI<DB0CZ<HB9EAS
Sent: 060714/0941z @:HB9EAS.CHE.EU [Basel JN37TM] DP6.00 $:J2E07VHB9EAS
From: HB9ABX @ HB9EAS.CHE.EU (Felix)
To:   ANT @ WW 


Here follows the field strength data of the
RoomCap Antenna.

This allows, among others, to determine the
security distance for the EMF regulation.

Field measurements performed 5th.July 2006
------------------------------------------

performed by HB9BWN and HB9ABX
sport field Bachgraben / Basel-Allschwil

Measured antenna:RoomCap 20m (w/o top capacity)

Transmit frequency = 14 Mhz

Distance = horizontal distance sensor to radiator
Height = height of sensor above ground
Ant-Height = height of Varylink above ground
Input power to antenna = 100 W


E-sensor / Ant-Height = 50cm / 100 W 
------------------------------------

Distance = 10m	
    Height = 30cm / 1m / 1,5m / 2m
             4,6   6,0   8,3    9,1  V/m

Distance = 5m
    Height = 30cm / 1m / 1,5m /  2m
             8,8  11,7  13,2   14,7  V/m
	
Distance = 4m
    Height = 30cm / 1m / 1,5m /  2m
             10,8  13,3  17,1   18,2 V/m

Distance = 3m
    Height = 30cm / 1m / 1,5m /  2m
             14,2  20,2  22,3   23,4 V/m

Distance = 2m
    Height = 30cm / 1m  / 1,5m /  2m
             21,5  34,6  41,2   42,6 V/m



H-sensor/ Ant-Height = 50cm / 100 W 
-----------------------------------

Distance = 10m
    Height = 30cm / 1m / 1,5m /  2m		
             15    14    13      13 mA/m

Distance = 5m
    Height = 30cm / 1m  / 1,5m /  2m
             27    26     25      24 mA/m

Distance = 4m
    Height = 30cm / 1m  / 1,5m /  2m
             35     32    30      29 mA/m

Distance = 3m
    Height = 30cm / 1m  / 1,5m /  2m
             49     47    41      39 mA/m

Distance = 2m
    Height = 30cm / 1m  / 1,5m /  2m
             77     72    61      55 mA/m

Distance = 1m
    Height = 30cm / 1m  / 1,5m /  2m
            150    181    137    115 mA/m


Measuring instrument:

Wandel&Goltermann
Type = EMR-200
Serie = BN 2244/21

H-sensor = 12.1 / 2244 / 90.28
E-sensor =  8.2 / 2244 / 90.20
 